How does FM Global's physics-based approach calculate panel resilience against hail in specific counties?
Answered at 23:00 in Resilience is Expensive, Except in Retrospect - Michael Perron (FM) · Raptor Report
How does FM Global's physics-based approach calculate panel resilience against hail in specific counties?
FM Global uses internal hail maps developed by meteorologists for specific counties in Texas, then compares these to the design of the system being built, including which panel is used and stow angle. They calculate the kinetic energy that will hit the panel on a 1-in-50-year hail basis and determine how many joules of impact the panel needs to withstand, allowing them to specify the panel correctly for that angle and location.
Full answer and detailsRead the whole answer, key facts and every other question from this episode
In short
FM Global uses internal hail maps developed by meteorologists for specific counties in Texas, then compares these to the design of the system being built, including which panel is used and stow angle.
Michael Perron, Renewable Energy Market Lead at FM Global · Resilience is Expensive, Except in Retrospect - Michael Perron (FM) · Raptor Report · answer at 23:00
Key takeaways
- FM Global uses internal hail maps developed by meteorologists for specific counties in Texas, then compares these to the design of the system being built, including which panel is used and stow angle.
Quote to remember
“Resilience is expensive, except in retrospect.”
— Michael Perron
The full answer · about 2 min
FM Global uses internal hail maps developed by meteorologists for specific counties in Texas, then compares these to the design of the system being built, including which panel is used and stow angle. They calculate the kinetic energy that will hit the panel on a 1-in-50-year hail basis and determine how many joules of impact the panel needs to withstand, allowing them to specify the panel correctly for that angle and location.
Key facts
- 2019: $75 million hail loss that insurers were not expecting
- 2022: Three major hail events in Texas ranging from $30 to $50 million each
- KWH Analytics data shows hail losses represent 73% of what insurers pay out
- 1-in-50-year hail basis used in FM Global's kinetic energy calculations
- FM Global: 6,000 total employees with 2,000 engineers on staff
People, companies and topics mentioned
More answers from this episode
- 3:00Why did FM Global and VDE separately verify Colin Sillerud's research on 75-degree panel stow angles at PVRW 2024?
- 10:00What was the financial impact of major hail losses on solar insurers between 2019 and 2022?
- 12:50Did insurers blacklist solar projects in Texas following major hail losses?
- 15:20What percentage of solar insurance losses does KWH Analytics data attribute to hail damage?
- 28:00What role do hail sensors play in solar project resilience monitoring and loss prevention?